Flexitanks provide an efficient way to transport compatible non-hazardous bulk liquids inside standard freight containers. However, successful transportation depends on more than the flexitank itself. Container selection, installation, loading, transportation, unloading, and post-use handling all form part of the operating process.
A typical flexitank operation includes six stages: container preparation, flexitank installation, liquid loading, transportation, unloading, and disposal or recycling. Each stage should follow the manufacturer's instructions and applicable industry requirements. The Container Owners Association's Code of Practice specifically treats the flexitank as part of a complete system that includes the container, flexitank, fittings, and restraining system.
Before installing a flexitank, the container should be checked carefully.The container should be:
Structurally sound
Clean and dry
Free from sharp edges
Free from protruding nails or damaged flooring
Free from residues or odors that could contaminate the cargo
Suitable for the selected flexitank system
BLT recommends careful container inspection and preparation before loading. Its own guidance highlights container cleanliness, floor condition, door condition, and appropriate protective materials as important considerations.
A suitable bulkhead and protective lining may also be installed according to the flexitank manufacturer's instructions.
The flexitank is positioned inside the prepared container. Unlike traditional liquid packaging methods that require multiple drums or IBC tanks, flexi bags for containers provide an efficient way to convert standard shipping containers into bulk liquid transportation units. During installation, the flexitank must be correctly positioned to ensure proper filling performance, load distribution, and transportation safety.
The installation normally includes:
Preparing the container floor.
Installing protective lining where required.
Positioning the flexitank correctly.
Installing the bulkhead or restraining system.
Aligning the outlet valve with the container opening.
Installing reinforcement components where specified.
Checking the flexitank for visible damage.
The flexitank should be installed by trained personnel and positioned according to the manufacturer's instructions. The COA Code of Practice emphasizes that flexitanks should only be fitted and positioned by appropriately trained personnel.
BLT also provides fitting instructions, technical support, and installation assistance for customers who require operational guidance.
After installation, the loading system should be prepared.
Depending on the cargo and facility, equipment may include:
Product storage tank
Suitable pump
Loading hose
Couplings or adapters
Hose supports
Flow-control equipment
Weighing or measurement equipment
The loading hose should be properly connected and supported to prevent unnecessary stress on the flexitank valve or connection point.
Before starting, operators should confirm that the correct cargo is being loaded into the correct flexitank and that the loading equipment is compatible with the product.
Loading should begin in a controlled manner. Operators should always follow the manufacturer's recommended procedures and installation instructions before starting the filling operation. A detailed flexitank loading procedure helps ensure correct valve connection, appropriate filling speed, proper liquid distribution, and safe operation throughout the process.
The operator should:
Confirm the valve connection.
Start the pump or loading system gradually.
Monitor the flow rate.
Check the flexitank position during filling.
Watch for leakage around valves and fittings.
Avoid introducing excessive air.
Monitor the loading temperature.
Stop when the approved quantity has been reached.
BLT's guidance specifically recommends controlled filling, appropriate flow rates, temperature monitoring, and avoiding overpressure.
The actual loading rate should follow the manufacturer's instructions and the characteristics of the cargo. High-viscosity liquids may require different loading conditions from low-viscosity liquids.
Once loading is complete, the valve and associated fittings should be secured according to the manufacturer's instructions.
The operator should verify:
Loaded quantity
Container gross weight
Valve condition
Bulkhead condition
Flexitank positioning
Required markings and documentation
The container can then enter the appropriate transportation network.
Flexitanks can support marine, inland, railway, and intermodal transportation depending on the product and transport arrangement. BLT's food-grade flexitank specifications identify inland, marine, railway, and intermodal freight transport as applicable transport modes.
The flexitank container unloading location should be prepared before opening the flexitank system.
The container should be positioned on a suitable, stable surface, and the receiving tank or storage system should be ready.
Operators should verify:
Receiving capacity
Hose compatibility
Valve connection
Pump requirements
Cargo temperature
Spill-control measures
Personal protective equipment
For viscous or temperature-sensitive liquids, heating equipment may be required before or during unloading. BLT offers several heating pad configurations, including electric and steam heating solutions, for applications where temperature control is required.
The unloading process should be controlled to minimize product loss and prevent damage to the flexitank.
Depending on the cargo and installation, the liquid may be discharged using gravity or suitable pumping equipment.
During unloading:
Connect the discharge hose securely.
Open the valve according to the operating procedure.
Control the discharge rate.
Monitor the receiving tank.
Avoid unnecessary pressure on the flexitank.
Check for leakage.
Minimize remaining liquid.
BLT specifically recommends placing the container on a level surface and using approved pumping equipment with pressure control where appropriate.
After unloading, the used flexitank should be handled according to the manufacturer's disposal or recycling procedure and local requirements.
The Container Owners Association notes that recycling arrangements can involve processing the used flexitank into a manageable state, while metal restraint components and cardboard lining may be recycled separately.
BLT also provides a dedicated flexitank disposal procedure through its download center.
Several operational mistakes can increase the risk of leakage, contamination, or cargo loss. Common examples include:
Using an unsuitable container
Failing to inspect the container floor
Incorrect valve positioning
Poor hose support
Excessive loading speed
Overfilling
Ignoring cargo temperature
Using incompatible equipment
Improper unloading pressure
Inadequate operator training
Following a documented checklist can make the process more consistent.
Loading time varies according to the liquid viscosity, pump, hose configuration, facility, and loading rate. It should follow the manufacturer's operating instructions rather than a universal time target.
Yes. Suitable pumping equipment can be used when compatible with the flexitank system and cargo. The flow rate and pressure should remain within the manufacturer's recommended limits.
Depending on the cargo, container position, valve configuration, and receiving system, gravity discharge may be possible. Pump-assisted unloading may be more appropriate for viscous liquids.
Some high-viscosity or temperature-sensitive liquids may require heating to maintain suitable flow characteristics. BLT offers steam and electric heating pad solutions for relevant applications.
Used flexitanks should be handled according to the manufacturer's disposal or recycling procedure and applicable local requirements. Choosing experienced flexi tank manufacturers is also important for ensuring reliable product quality, technical support, and application guidance. BLT provides flexitank installation assistance, loading and unloading support, and customized solutions for different liquid transportation requirements.
Flexitank loading and unloading should be treated as a complete operational process rather than a simple filling and emptying procedure. Proper container preparation, correct installation, controlled loading, secure transportation, and careful unloading all contribute to cargo integrity and transport safety.
A standardized operating procedure, trained personnel, suitable equipment, and manufacturer-specific instructions can help reduce operational risks and improve bulk liquid transportation efficiency.
Container Owners Association – Flexitank Technical Resource: COA Flexitanks
COA Code of Practice: COA Code of Practice for Flexitank Container Systems